121-31A18024B Norden Cat 6 UTP Angled Patch Panel Blank Tool less 24Port
121-31A18024B Norden
DESCRIPTION
The Unshielded angled patch panels are ideal for Data centerapplications where rack space is limited. These ergonomically designed panel provide aesthetic look combined with easy cable management. It exceeds TIA and ISO Component specifications, supporting network convergence protocols delivering maximum bandwidth and extending reliability for LAN, multimedia, and power over Ethernet applications The rear cable management bar also acts as a stress reliever along with the function of managing cable. All performance parameters, including NEXT, FEXT Attenuation and Return Loss are designed to meet the Cabling standard. 19” (1U: 24 port & 2U: 48 port) patch panel comes with mini cable ties, cage nuts and rear cable management bar.
$ 44.38 -
121-31T18048B Norden Cat 6 UTP Patch Panel Blank Tool less 48 Port
121-31T18048B Norden
DESCRIPTION
Blank UTP Tool Less patch panel from Norden exceeds TIA and ISO component specifications, supporting network convergence protocols, delivering maximum bandwidth and extended reliability for all LAN, multimedia, and Power over Ethernet applications. Each port of the panel is numbered and has a designated label area for clear port identification. Keystone outlets can be snapped in to the 19’’ frame without the need for tooling of any type and is supplied in unloaded version.The tool-less jack termination offers fast and reliable installation of unshielded cable, quick and easy in termination. A rear cable management bar is supplied which acts as a stress reliever of terminated cables. The patch panel comes with mini cable ties, cage nuts and rear cable management bar as standard. Enhanced cable retention fixture and unique assembly. Supports solid 22-24 AWG wires and stranded 24-26 AWG.
$ 46.28 -
121-01P18124B Norden Cat 6 UTP Patch Panel Blank Punch Down 24 Port
121-01P18124B Norden
DESCRIPTION
Blank UTP Punch Down patch panel from Norden exceeds TIA and ISO component specifications, supporting network convergence protocols, delivering maximum bandwidth and extended reliability for all LAN, multimedia, and Power over Ethernet applications. A rear cable management bar is supplied which acts as a stress reliever for terminated cables. All performance parameters, including NEXT, FEXT Attenuation and Return Loss are designed to meet the Cabling standard. The patch panel comes with mini cable ties, cage nuts and rear cable management bar as standard.
$ 14.16 -
122-21P090X Norden Category 5e UTP Keystone Jack 90D
Norden 122-21P090X
Category 5e UTP Keystone Jack 90D
DESCRIPTION
Colour Black And White or Others Available Upon Request
Size 35.1 mm X 17.1 mm X 25.2 mm
RJ45 Port 11.8 mm X 9.8 mm
Angle 90 Degree
Temperature -Storage -40 °C to +70 °C
Temperature -Operation -10 °C to +65 °C
Housing Material High Impact, Flame-Retardant Plastic Compound, Ul 94 V-0.
IDC Type Dual (110 Or Krone) Type$ 2.18 -
N424.532 Nexans UK Style Backbox Single Gang White
Nexans N424.532
UK Style Backbox Single Gang White
DESCRIPTION
LANmark Snap-In Modules in standard UK styles
· 25 x 50 mm angled and flat shuttered modules for 1 LANmark Snap-In connector
· LJ6C angled and flat shuttered modules for 1 LANmark Snap-In connector
· 50 x 50 mm angled shuttered modules for 2 LANmark Snap-In connectors$ 2.45 -
N116.P1A200OK Nexans LANmark-6 Patch Cord Cat 6 Unscreened LSZH 20m Orange
N116.P1A200OK Nexans
DESCRIPTION
Application
LANmark-6 Patch Cords can be used to deliver a full end-to-end Class E solution. They provide improved data throughput and allow for the inclusion of a cross-connect or Consolidation Points for maximum system flexibility. They will also maximise the lifetime and long term performance of the system by minimising the risk of wear & tear damage which can be caused by using non-matched cords. LANmark-6 Cords feature a slim over-moulded boot which is kept inside the RJ45 boundaries to enable High Density Patching with 48 cords in 1 height unit. They also come with a Retrofit Latch Protector, which can be used for colour coding of different services.$ 27.23 -
N116.P1A050OK Nexans LANmark-6 Patch Cord Cat 6 Unscreened LSZH 5m Orange.
N116.P1A050OK Nexans
DESCRIPTION
Application
LANmark-6 Patch Cords can be used to deliver a full end-to-end Class E solution. They provide improved data throughput and allow for the inclusion of a cross-connect or Consolidation Points for maximum system flexibility. They will also maximise the lifetime and long term performance of the system by minimising the risk of wear & tear damage which can be caused by using non-matched cords. LANmark-6 Cords feature a slim over-moulded boot which is kept inside the RJ45 boundaries to enable High Density Patching with 48 cords in 1 height unit. They also come with a Retrofit Latch Protector, which can be used for colour coding of different services.$ 11.71 -
N116.P1A030OK Nexans LANmark-6 Patch Cord Cat 6 Unscreened LSZH 3m Orange.
N116.P1A030OK Nexans
DESCRIPTION
Application
LANmark-6 Patch Cords can be used to deliver a full end-to-end Class E solution. They provide improved data throughput and allow for the inclusion of a cross-connect or Consolidation Points for maximum system flexibility. They will also maximise the lifetime and long term performance of the system by minimising the risk of wear & tear damage which can be caused by using non-matched cords. . LANmark-6 Cords feature a slim over-moulded boot which is kept inside the RJ45 boundaries to enable High Density Patching with 48 cords in 1 height unit. They also come with a Retrofit Latch Protector, which can be used for colour coding of different services.
$ 7.02 -
N116.P1A020OK Nexans LANmark-6 Patch Cord Cat 6 Unscreened LSZH 2m Orange
N116.P1A020OK Nexans
DESCRIPTION
Application
LANmark-6 Patch Cords can be used to deliver a full end-to-end Class E solution. They provide improved data throughput and allow for the inclusion of a cross-connect or Consolidation Points for maximum system flexibility. They will also maximise the lifetime and long term performance of the system by minimising the risk of wear & tear damage which can be caused by using non-matched cords. LANmark-6 Cords feature a slim over-moulded boot which is kept inside the RJ45 boundaries to enable High Density Patching with 48 cords in 1 height unit. They also come with a Retrofit Latch Protector, which can be used for colour coding of different services.
$ 6.81 -
N205.624 Nexans LANmark-OF Duplex SC Snap-In Adaptor Singlemode
N205.624 Nexans
DESCRIPTION
LANmark-OF Snap-In adapters have been designed for installation into the LANmark- OF snap-in panels, ZD boxes and outlets. They are available in single SC, duplex SC and duplex LC duplex. The multimode adaptors are aqua, the singlemode adaptors are blue while the singlemode APC adaptors are green. Installation time is saved as the snap-in concept replaces the time-consuming screwing attachment of coupling devices.
$ 8.20 -
N123.4MCY Nexans LANmark-OF Pigtail SC/UPC Singlemode Maxistrip LSZH 9/125 1m Yellow
N123.4MCY Nexans
DESCRIPTION
Pigtail characteristics
• Fibre assembly to terminate cable with fusion splicing
• Suitable for use in patch panels using splice cassettes.
• The pigtails can be stripped in one action over a long distance up to 100cm.Fibre type
The LANmarkOF SM pigtails have LANmarkOF SM GIGAliteFLEX fibre inside. These fibres are bend insensitive and compliant to ITUT G.657.A1 and to IEC 60793250, fibre model B6.a1. The pigtail jacket of the singlemode pigtails is yellow.
Compatibility and installation practices
- Maxistrip pigtails are compatible with heat shrink splice cassettes (N890.090 and N890.095) with heat shrink protectors (N890.021).
- Maxistrip pigtails are compatible with splice cassettes (N890.091 and N890.096) with Aluminium protectors (N890.021).
- Maxistrip pigtails are recommended to be used with loose tube cables or MicroBundle cables, i.e. with 250 um fibres. When using tight buffer cables (900 um fibres) additional stress on the maxistrip pigtails should be limited as much as possible
- For proper alignment in the fusion splice tool the pigtail is fixed on the 250 um coating after stripping the 900 um coating. Fixing the pigtail on the 900 um coating will lead to improper alignment.
- In addition the pigtail needs to be stripped till the cladding around the splice area before insertion in the splice tool.
$ 5.72 -
N121.4MLY Nexans LANmark-OF Pigtail LC/UPC Singlemode Maxistrip LSZH 9/125 1m Yellow
N121.4MLY Nexans
DESCRIPTION
Pigtail characteristics
• Fibre assembly to terminate cable with fusion splicing
• Suitable for use in patch panels using splice cassettes.
• The pigtails can be stripped in one action over a long distance up to 100cm.Fibre type
The LANmarkOF SM pigtails have LANmarkOF SM GIGAliteFLEX fibre inside. These fibres are bend insensitive and compliant to ITUT G.657.A1 and to IEC 60793250, fibre model B6.a1. The pigtail jacket of the singlemode pigtails is yellow.
Compatibility and installation practices
Maxistrip pigtails are compatible with heat shrink splice cassettes (N890.090 and N890.095) with heat shrink protectors (N890.021).
Maxistrip pigtails are compatible with splice cassettes (N890.091 and N890.096) with Aluminium protectors (N890.021).
Maxistrip pigtails are recommended to be used with loose tube cables or Micro Bundle cables, i.e. with 250 um fibres. When using tight buffer cables (900 um fibres) additional stress on the maxistrip pigtails should be limited as much as possible
For proper alignment in the fusion splice tool the pigtail is fixed on the 250 um coating after stripping the 900 um coating. Fixing the pigtail on the 900 um coating will lead to improper alignment.
In addition the pigtail needs to be stripped till the cladding around the splice area before insertion in the splice tool.
$ 5.53