• 127-31102BL Norden Category 6 U/UTP Patch Cord PVC 02M Blue

    127-31102BL Norden

    DESCRIPTION

    Norden Category 6 UTP patch cords are manufactured using high quality unshielded four pair Category 6 stranded cable, and feature cable strain relief boots with a plug latch protection cap. This patch cord when used with high performance Norden Category 6 connectivity (solid UTP cable,patch panels and work area outlets), provide superior performance capabilities of high bandwidth (Gigabit 1000Base-T and 1000Base-Tx)applications support. This is fully backward compatible to Category 5e (Class D) products.Each patch cord is tested with Fluke tester and individual cover includewith the report. Norden Category 6 Patch cord is tested for transmission frequencies of up to 250 MHz.

  • 127-31102GN Norden Category 6 U/UTP Patch Cord PVC 02M Green

    127-31102GN Norden

    DESCRIPTION

    Norden Category 6 UTP patch cords are manufactured using high quality unshielded four pair Category 6 stranded cable, and feature cable strain relief boots with a plug latch protection cap. This patch cord when used with high performance Norden Category 6 connectivity (solid UTP cable,patch panels and work area outlets), provide superior performance capabilities of high bandwidth (Gigabit 1000Base-T and 1000Base-Tx)applications support. This is fully backward compatible to Category 5e (Class D) products.Each patch cord is tested with Fluke tester and individual cover includewith the report. Norden Category 6 Patch cord is tested for transmission frequencies of up to 250 MHz.

  • 127-31102GY Norden Category 6 U/UTP Patch Cord PVC 02M Grey

    127-31102GY Norden

    DESCRIPTION

    Norden Category 6 UTP patch cords are manufactured using high quality unshielded four pair Category 6 stranded cable, and feature cable strain relief boots with a plug latch protection cap. This patch cord when used with high performance Norden Category 6 connectivity (solid UTP cable,patch panels and work area outlets), provide superior performance capabilities of high bandwidth (Gigabit 1000Base-T and 1000Base-Tx)applications support. This is fully backward compatible to Category 5e (Class D) products.Each patch cord is tested with Fluke tester and individual cover includewith the report. Norden Category 6 Patch cord is tested for transmission frequencies of up to 250 MHz.

  • 127-31102YL Norden Category 6 U/UTP Patch Cord PVC 02M Yellow

    127-31102YL Norden

    DESCRIPTION

    Norden Category 6 UTP patch cords are manufactured using high quality unshielded four pair Category 6 stranded cable, and feature cable strain relief boots with a plug latch protection cap. This patch cord when used with high performance Norden Category 6 connectivity (solid UTP cable,patch panels and work area outlets), provide superior performance capabilities of high bandwidth (Gigabit 1000Base-T and 1000Base-Tx)applications support. This is fully backward compatible to Category 5e (Class D) products.Each patch cord is tested with Fluke tester and individual cover includewith the report. Norden Category 6 Patch cord is tested for transmission frequencies of up to 250 MHz.

  • 127-31103BL Norden Category 6 U/UTP Patch Cord PVC 03M Blue

    127-31103BL Norden

    DESCRIPTION

    Norden Category 6 UTP patch cords are manufactured using high quality unshielded four pair Category 6 stranded cable, and feature cable strain relief boots with a plug latch protection cap. This patch cord when used with high performance Norden Category 6 connectivity (solid UTP cable,patch panels and work area outlets), provide superior performance capabilities of high bandwidth (Gigabit 1000Base-T and 1000Base-Tx)applications support. This is fully backward compatible to Category 5e (Class D) products.Each patch cord is tested with Fluke tester and individual cover includewith the report. Norden Category 6 Patch cord is tested for transmission frequencies of up to 250 MHz.

  • 127-31103GY Norden Category 6 U/UTP Patch Cord PVC 03M Grey

    127-31103GY Norden

    DESCRIPTION

    Norden Category 6 UTP patch cords are manufactured using high quality unshielded four pair Category 6 stranded cable, and feature cable strain relief boots with a plug latch protection cap. This patch cord when used with high performance Norden Category 6 connectivity (solid UTP cable,patch panels and work area outlets), provide superior performance capabilities of high bandwidth (Gigabit 1000Base-T and 1000Base-Tx)applications support. This is fully backward compatible to Category 5e (Class D) products.Each patch cord is tested with Fluke tester and individual cover includewith the report. Norden Category 6 Patch cord is tested for transmission frequencies of up to 250 MHz.

  • 341-1OS2S315 Norden SC APC Pigtail OS2 PVC 1.5m

    Norden 341-1OS2S315 SCAPC Pigtail OS2 PVC 1.5m

    MECHANICAL DATA
    COMPLIANCE
    ISO/IEC 11801
    EN50173 -1,ANSI TIA/EIA 568B
    FIBRE PIGTAIL
    Fibre pigtails are used in permanent connections between patch
    panels and incoming cables / single blown fibres. Pigtails are preconstructed
    with connectors. Connector options include small form
    factors such as LC, E2000 and MT-RJ as well as SC, FC and ST. These are
    based on 900μm tight buffered cores (600μm MT-RJ) and suitable for
    internal use only inside suitable Fibre Management Systems
    www.nordencommunication.com
    Fibre System
    Crush (N) 800
    Impact (Nm) 0.2
    Operating Temperature -10°C to +70°C
    Installation temperature 0°C to +70°C
    Temp – Installation 0°C to +70°C
    Bend Radius 50mm (min)
    Fibre Type Max. Attenuation
    (dB/km)
    850nm 1300nm 1310nm 1550nm
    OM1 62.5/125μm ≤2.7 ≤0.6 – –
    OM2 50/125μm ≤2.5 ≤0.7 – –
    OM3 50/125μm ≤2.3 ≤0.6 – –
    OM4 50/125μm ≤2.3 ≤0.6 – –
    OS1 9/125μm – – ≤0.34 ≤0.20
    OS2 9/125μm – – ≤0.34 ≤0.24
    Min. Overfill Launch
    Bandwidth
    (Mhz•km)
    Min. Gigabit Ethernet Link
    Distance (m)
    Gigabit 10Gigabit
    850nm 1300nm 850nm 1300nm 850nm
    ≥200 ≥600 275 550 –
    ≥500 ≥500 550 550 –
    ≥1500 ≥500 1000 600 300
    ≥3500 ≥500 1000 600 550
    – – – – –
    – – – – –
    OPTICAL PERFORMANCE DATA (CONNECTOR)
    ORDERING INFORMATION
    ORDERING GUIDE
    www.nordencommunication.com
    Fibre System
    FIBRE PIGTAIL
    Description Part Number
    Singlemode OS2
    SC/APC 1m PVC SC/APC OS2 PVC 1M PIGTAIL 341-1OS2S310
    SC/APC 1.5m PVC SC/APC OS2 PVC 1.5M PIGTAIL 341-1OS2S315
    SC/APC 2m PVC SC/APC OS2 PVC 2M PIGTAIL 341-1OS2S320
    SC/APC 3m PVC SC/APC OS2 PVC 3M PIGTAIL 341-1OS2S330
    SC/APC 1m LSZH SC/APC OS2 LSZH 1M PIGTAIL 342-1OS2S310
    SC/APC 1.5m LSZH SC/APC OS2 LSZH 1.5M PIGTAIL 342-1OS2S315
    SC/APC 2m LSZH SC/APC OS2 LSZH 2M PIGTAIL 342-1OS2S320
    SC/APC 3m LSZH SC/APC OS2 LSZH 3M PIGTAIL 342-1OS2S330

  • OPTRONICS OPPC-XX-1-24-UL

    OPTRONICS OPPC-XX-1-24-UL

     

    Unloaded 1u KeyStone Panel Frame

  • 121-01P18124B NORDEN Category 6 UTP Patch Panel Blank Punch Down 24 Port

    NORDEN 121-01P18124B

    Category 6 UTP Patch Panel Blank Punch Down 24 Port

    DESIGN & MATERIALS
    Panel Type Flat
    Panel Style Blank
    Mounting Style Punch Down (Module)
    Panel Width 483 mm (19”)
    Panel Height 1U: 44.2 mm & 2U: 88.4 mm
    Panel Depth 109 mm
    Outlet Style Unkeyed RJ-45
    Outlets 24/48 Port
    Connector Module Holder High Impact, Flame-Retardant Plastic Compound, Ul 94 V-0
    Cover Colour and Material Black, Powder Coated Steel

    STANDARDS
    Wiring Standards EIA/TIA 568 A/B
    Flammability rating UL 94V-0
    Safety Rating UL1863
    Transmission ISO/IEC 11801:2002 ANSI /TIA/EIA-568.B.2-10

  • 121-01P18124B Norden Cat 6 UTP Patch Panel Blank Punch Down 24 Port

    121-01P18124B Norden

    DESCRIPTION

    Blank UTP Punch Down patch panel from Norden exceeds TIA and ISO component specifications, supporting network convergence protocols, delivering maximum bandwidth and extended reliability for all LAN, multimedia, and Power over Ethernet applications. A rear cable management bar is supplied which acts as a stress reliever for terminated cables. All performance parameters, including NEXT, FEXT Attenuation and Return Loss are designed to meet the Cabling standard. The patch panel comes with mini cable ties, cage nuts and rear cable management bar as standard.

  • 1331-106E06N001BK NORDEN 6 Way PDU with Main Switch, 13Amp, 1.8mtr, 19” Installation

    NORDEN 1331-106E06N001BK

    POWER DISTRIBUTION UNIT

    DESIGN & MATERIALS
    Material of Construction PC/ABS alloy, High Impart FR thermoplastic –UlL94-V0
    Shell Material & Colour Aluminium, black
    Outlet Qty. 6 way, 8 way, 10 way,12 way, 15 way
    Power Input Style Left end single input style
    Bracket Installation Style Frontal Installation Style
    Control function Switch

    Lead length 1.8 m, 3 m, 5 m (other cable length available on request)

    ELECTRICAL & ENVIRONMENTAL DATA

    Current Rating 13A 250VAC
    Maximum load current available in 13A
    Input frequency 50 or 60 Hz
    Maximum load capacity 4KW
    Operating Environment -5 °C to +45 °C
    Operating Relative Humidity 5 – 95 %
    Operating Elevation 0-3000 meters
    Storage Temperature -25 °C to +65 °C
    Storage Relative Humidity 5 – 95 %
    Storage Elevation 0-15000 meters

  • 121-31T18024B NORDEN Category 6 UTP Patch Panel Blank Tool Less 24 Port

    NORDEN 121-31T18024B

    Category 6 UTP Patch Panel Blank Tool Less 24 Port

    DESIGN & MATERIALS
    Panel Type Flat
    Panel Style Blank
    Mounting Style Tool Less (Module)
    Panel Width 483 mm (19”)
    Panel Height 1U: 44.0 mm, 2U: 88.4 mm
    Panel Depth 79.5 mm
    Outlet Style Unkeyed RJ-45
    Outlets 24 & 48 Ports
    IDC Contact 45° secure, gas tight connection
    Connector Module Holder High Impact, Flame-Retardant Plastic Compound, UL 94 V-0
    Cover Colour and Material Black, Powder Coated Steel
    STANDARDS
    Wiring Standards EIA/TIA 568 A/B
    Flammability rating UL 94V-0
    Safety Rating UL1863

Main Menu