341-1OS2S315 Norden SC APC Pigtail OS2 PVC 1.5m
Norden 341-1OS2S315 SCAPC Pigtail OS2 PVC 1.5m
MECHANICAL DATA
COMPLIANCE
ISO/IEC 11801
EN50173 -1,ANSI TIA/EIA 568B
FIBRE PIGTAIL
Fibre pigtails are used in permanent connections between patch
panels and incoming cables / single blown fibres. Pigtails are preconstructed
with connectors. Connector options include small form
factors such as LC, E2000 and MT-RJ as well as SC, FC and ST. These are
based on 900μm tight buffered cores (600μm MT-RJ) and suitable for
internal use only inside suitable Fibre Management Systems
www.nordencommunication.com
Fibre System
Crush (N) 800
Impact (Nm) 0.2
Operating Temperature -10°C to +70°C
Installation temperature 0°C to +70°C
Temp – Installation 0°C to +70°C
Bend Radius 50mm (min)
Fibre Type Max. Attenuation
(dB/km)
850nm 1300nm 1310nm 1550nm
OM1 62.5/125μm ≤2.7 ≤0.6 – –
OM2 50/125μm ≤2.5 ≤0.7 – –
OM3 50/125μm ≤2.3 ≤0.6 – –
OM4 50/125μm ≤2.3 ≤0.6 – –
OS1 9/125μm – – ≤0.34 ≤0.20
OS2 9/125μm – – ≤0.34 ≤0.24
Min. Overfill Launch
Bandwidth
(Mhz•km)
Min. Gigabit Ethernet Link
Distance (m)
Gigabit 10Gigabit
850nm 1300nm 850nm 1300nm 850nm
≥200 ≥600 275 550 –
≥500 ≥500 550 550 –
≥1500 ≥500 1000 600 300
≥3500 ≥500 1000 600 550
– – – – –
– – – – –
OPTICAL PERFORMANCE DATA (CONNECTOR)
ORDERING INFORMATION
ORDERING GUIDE
www.nordencommunication.com
Fibre System
FIBRE PIGTAIL
Description Part Number
Singlemode OS2
SC/APC 1m PVC SC/APC OS2 PVC 1M PIGTAIL 341-1OS2S310
SC/APC 1.5m PVC SC/APC OS2 PVC 1.5M PIGTAIL 341-1OS2S315
SC/APC 2m PVC SC/APC OS2 PVC 2M PIGTAIL 341-1OS2S320
SC/APC 3m PVC SC/APC OS2 PVC 3M PIGTAIL 341-1OS2S330
SC/APC 1m LSZH SC/APC OS2 LSZH 1M PIGTAIL 342-1OS2S310
SC/APC 1.5m LSZH SC/APC OS2 LSZH 1.5M PIGTAIL 342-1OS2S315
SC/APC 2m LSZH SC/APC OS2 LSZH 2M PIGTAIL 342-1OS2S320
SC/APC 3m LSZH SC/APC OS2 LSZH 3M PIGTAIL 342-1OS2S330$ 6.81 -
351-SSCSC02 Norden SC/APC Singlemode Simplex Adaptor
Norden 351-SSCSC02
OPTICAL PERFORMANCE DATA
Item Single mode Multimode
PC UPC APC 62.5/125 50/125 50/125
10G
Insert. Loss/Adaptor (single Fibre) 0.2 dB Max. (0.15 dB typ.) 0.3 dB Max. (0.25 dB typ.)
Return Loss ≥ 45 dB ≥ 50 dB ≥ 60 dB N.A
Insert. Loss/MTRJ 0.5dB Max. (0.45 dB typ.) 0.5 dB max. (0.45 dB typ.)
Pull strength ≥ 98 N ≥ 98 N ≥ 98 N ≥ 98 N$ 1.91 -
352-SLCLC02SH Norden SM Fiber LC Adaptor
Norden 352-SLCLC02SH
APPLICATIONS
CATV
Active device/Transceiver, Telecommunication networks
Multimedia Data processing networks
Test equipment, Premise installations
Gigabit Ethernet
Adaptor Material High Impart flame retardant thermoplastic UL94-V0
Capillary Diameter Tolerance (Single Mode) 126 ± 0.5 μm
Capillary Diameter Tolerance( Multimode) 127 ± 0.5 μm
Operating Temperature -40 ºC to +85 ºC
Storage Temperature: -40 ºC to +85 ºC
Mating Durability > 500 Mating Cycles
ORDERING INFORMATION
Part Number Description
351-SLCLC LC Singlemode Simplex Adaptor
351-SLCLC02 LC/APC Singlemode Simplex Adaptor
351-MLCLC LC Multimode Simplex Adaptor
352-SLCLC LC Singlemode Duplex Adaptor
352-SLCLC02 LC/APC Singlemode Duplex Adaptor
352-MLCLC LC Multimode Duplex Adaptor
351-SLCLCSH LC Singlemode Simplex Shutter Adaptor
351-SLCLC02SH LC/APC Singlemode Simplex Shutter Adaptor
351-MLCLCSH LC Multimode Simplex Shutter Adaptor
352-SLCLCSH LC Singlemode Duplex Shutter Adaptor
352-SLCLC02SH LC/APC Singlemode Duplex Shutter Adaptor
352-MLCLCSH LC Multimode Duplex Shutter Adaptor$ 2.99 -
421-1SC024BK NORDEN SC Simplex 24 Port EFA Fibre Optic Compact Patch Panel Rack Mount
NORDEN 421-1SC024BK
FIBRE OPTIC EASY FRONT ACCESS COMPACT PATCH PANEL
FEATURES
Easy front access .
Front Panel equiped with adaptors.
Sliding patch panel for easy rework and maintenance.
Cable clamps on the inner surface for fixing cables.
19 ̋ rack mount 1U Size.
Fixed Splice tray for splice utilisation designed with plexi glass top – cover & PC material .
Patch panels for SC,LC,ST,FC,MTRJ & E2000.
The enclosure is made of cold rolled steel sheet, with electrostatic – spraying.DESIGN & MATERIALS
Mounting Type Rack
Colour Black or Beige or white
Material Cold rolled carbon sheet steel with electrostatic spraying
FIBRE OPTIC EASY FRONT ACCESS
COMPACT PATCH PANEL
Norden EFA Fiber Optic Compact Patch panel is designed for fiber
termination and distribution.This smart design and professional
engineering provides easy installation and maintenance
Rack Type Sliding
‘U’ Size 1U=12/24port
Cable Port Max. 2-4
Environment Temperature- Relative -40 ºC to +80 ºC
Humidity ≤85 % (30 degree)
Atmosphere Pressure 70-106 KPa
Intensity ≤15kv(DC) /1min.no spark-over and no flying arc
Fibre Bending Radius ≥ 40 mm
Material Thickness 2mm
Insulated Resistance ≥2*10M Ohm/500V (DC)
Adaptor Port Simplex$ 83.86 -
FWE-MOD-12-M-C AFL Modular DIN Rail Mounted Enclosure
AFL FWE-MOD-12-M-C
Modular DIN Rail Mounted Enclosure
DESCRIPTION
AFL specialises in the development of fibre optic enclosures to suit all environments and customer needs. We have developed a complete range to suit almost any application including 19” rack mounting, wall mounting, Defence style, IP-rated for outside
plant environments, industrial uses and for underground terminations.
Our extensive range of enclosures can accommodate a variety of installation applications including fusion splicing, directtermination, pre-terminated cables, MTP connectivity and pre-terminated copper cabling.
In addition, AFL can offer a customer tailored enclosure or cabinet solution to suit non-standard applications.$ 508.86 -
N102.105BK Nexans 1HU Patch Guide with Rings, Black
Nexans
Patch Guides, Blank Panels & Cable Management
· Patch guides to manage and store all patch cords.
· 1 HU and 2 HU for high density.
· 1 HU with rings for easy access.
· Cable guide for all patch panels without clip-on.$ 14.70 -
N116.P1A020OK Nexans LANmark-6 Patch Cord Cat 6 Unscreened LSZH 2m Orange
N116.P1A020OK Nexans
DESCRIPTION
Application
LANmark-6 Patch Cords can be used to deliver a full end-to-end Class E solution. They provide improved data throughput and allow for the inclusion of a cross-connect or Consolidation Points for maximum system flexibility. They will also maximise the lifetime and long term performance of the system by minimising the risk of wear & tear damage which can be caused by using non-matched cords. LANmark-6 Cords feature a slim over-moulded boot which is kept inside the RJ45 boundaries to enable High Density Patching with 48 cords in 1 height unit. They also come with a Retrofit Latch Protector, which can be used for colour coding of different services.
$ 6.81 -
N116.P1A030OK Nexans LANmark-6 Patch Cord Cat 6 Unscreened LSZH 3m Orange.
N116.P1A030OK Nexans
DESCRIPTION
Application
LANmark-6 Patch Cords can be used to deliver a full end-to-end Class E solution. They provide improved data throughput and allow for the inclusion of a cross-connect or Consolidation Points for maximum system flexibility. They will also maximise the lifetime and long term performance of the system by minimising the risk of wear & tear damage which can be caused by using non-matched cords. . LANmark-6 Cords feature a slim over-moulded boot which is kept inside the RJ45 boundaries to enable High Density Patching with 48 cords in 1 height unit. They also come with a Retrofit Latch Protector, which can be used for colour coding of different services.
$ 7.02 -
N116.P1A050OK Nexans LANmark-6 Patch Cord Cat 6 Unscreened LSZH 5m Orange.
N116.P1A050OK Nexans
DESCRIPTION
Application
LANmark-6 Patch Cords can be used to deliver a full end-to-end Class E solution. They provide improved data throughput and allow for the inclusion of a cross-connect or Consolidation Points for maximum system flexibility. They will also maximise the lifetime and long term performance of the system by minimising the risk of wear & tear damage which can be caused by using non-matched cords. LANmark-6 Cords feature a slim over-moulded boot which is kept inside the RJ45 boundaries to enable High Density Patching with 48 cords in 1 height unit. They also come with a Retrofit Latch Protector, which can be used for colour coding of different services.$ 11.71 -
N116.P1A200OK Nexans LANmark-6 Patch Cord Cat 6 Unscreened LSZH 20m Orange
N116.P1A200OK Nexans
DESCRIPTION
Application
LANmark-6 Patch Cords can be used to deliver a full end-to-end Class E solution. They provide improved data throughput and allow for the inclusion of a cross-connect or Consolidation Points for maximum system flexibility. They will also maximise the lifetime and long term performance of the system by minimising the risk of wear & tear damage which can be caused by using non-matched cords. LANmark-6 Cords feature a slim over-moulded boot which is kept inside the RJ45 boundaries to enable High Density Patching with 48 cords in 1 height unit. They also come with a Retrofit Latch Protector, which can be used for colour coding of different services.$ 27.23 -
N11A.U1F010OK Nexans LANmark-6A Ultim UniBoot Patch Cords, 1 mtrs
N11A.U1F010OK Nexans
DESCRIPTION
LANmark-6A Ultim cords are developed to support 10 Gigabit Ethernet (IEEE 802.3an)
and any other future Cat.6A application.
LANmark-6A Ultim Cords offer superior performance up to 500MHz and are matched
with other LANmark-6A components to provide improved data throughput in complex
channel configurations. Ultim cords use stranded cable and as such provide maximum
system flexibility for the use at Cross Connects and Consolidation points.
They will also maximise the lifetime and longevity of the system by minimising the risk
of wear & tear damage. Due to their good electrical performance and mechanical
stability, LANmark-6A Ultim cords can be used for accurate field testing of Cat 6A
cabling channels. .
Ultim Cords feature a slim boot for mechanical protection, which is kept inside the
RJ45 boundaries to enable High Density Patching with 48 cords in 1 height unit.
They also come with a ‘Replaceable’ Latch Protector, which can be used for colour
coding of different services.$ 7.08$ 7.62 -
N11A.U1F020OK Nexans LANmark-6A Ultim Patch Cord, 2 Meters
N11A.U1F020OK Nexans
DESCRIPTION
Application
LANmark-6A Ultim cords are developed to support 10 Gigabit Ethernet (IEEE 802.3an) and any other future Cat.6A application. LANmark-6A Ultim Cords offer superior performance up to 500MHz and are matched with other LANmark-6A components to provide improved data throughput in complex channel configurations. Ultim cords use stranded cable and as such provide maximum system flexibility for the use at Cross Connects and Consolidation points. They will also maximise the lifetime and longevity of the system by minimising the risk of wear & tear damage. Due to their good electrical performance and mechanical stability, LANmark-6A Ultim cords can be used for accurate field testing of Cat 6A cabling channels. Ultim Cords feature a slim boot for mechanical protection, which is kept inside the RJ45 boundaries to enable High Density Patching with 48 cords in 1 height unit. They also come with a ‘Replaceable’ Latch Protector, which can be used for colour coding of different services.$ 8.44$ 9.26